High Fire Specs.
HF 2318 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
23.5" Diameter x 18" Deep - 4.7 Cubic Feet
(59.7cm Diameter x 45.7cm Deep - 133L)
35.5" Long x 29.5" Wide x 32" High (includes the 8" stand)
(90.2cm Deep x 74.3cm Wide x 81.3cm High)
2350°F (1288°C) - Cone 10 max.
240 Volts, 31 Amps, 7440 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 6-50
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model is available in 200V, 208V, 220V and 230V
Model will operate properly on both 50Hz and 60Hz
Model is available in 3 phase Delta and Y (380V, 400V and 415V) designs
240lb. (109Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
HF models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.

HF 2327 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing

23.5" Diameter x 27" Deep - 7.0 Cubic Feet
(59.7cm Diameter x 68.6cm Deep - 198L)
35.5" Long x 29.5" Wide x 41" High (includes the 8" stand)
(90.2cm Deep x 74.3cm Wide x 104.1cm High)
2350°F (1288°C) - Cone 10 max.
240 Volts, 48 Amps, 11,520 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 6-50
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model is available in 200V, 208V, 220V and 230V
Model will operate properly on both 50Hz and 60Hz
Model is available in 3 phase Delta and Y (380V, 400V and 415V) designs
330lb. (150Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
HF models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.
HF 2918 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
29" Diameter x 18" Deep - 7.0 Cubic Feet
(73.7cm Diameter x 45.7cm Deep - 198L)
41" Long x 35" Wide x 32" High (includes the 8" stand)
(104.1cm Deep x 88.9cm Wide x 81.3cm High)
2350°F (1288°C) - Cone 10 max.
240 Volts, 48 Amps, 11,520 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 6-50
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model is available in 200V, 208V, 220V and 230V
Model will operate properly on both 50Hz and 60Hz
Model is available in 3 phase Delta and Y (380V, 400V and 415V) designs
350lb. (159Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
HF models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.

HF 2927 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
29" Diameter x 27" Deep - 10.5 Cubic Feet
(73.7cm Diameter x 68.6cm Deep - 297L)
41" Long x 35" Wide x 41" High (includes the 8" stand)
(104.1cm Deep x 88.9cm Wide x 104.1cm High)
2350°F (1288°C) - Cone 10 max.
240 Volts, 59 Amps, 14,164 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - Direct Wire
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model is available in 200V, 208V, 220V and 230V
Model will operate properly on both 50Hz and 60Hz
Model is available in 3 phase Delta and Y (380V, 400V and 415V) designs
430lb. (195Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
HF models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.