KH Specifications
KH 414 Specifications - At 13.5" deep the KH 414 is our shallowest model in the KH Series. It offers the smallest footprint which comes in handy when shop space is at a premium.

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
13.5" Deep x 6.5" Wide x 4.25" High - 0.22 Cubic Feet
(34.3cm Deep x 16.5cm Wide x 10.8cm High - 6.2L)
19" Deep x 16.5" Wide x 17.25" High (includes the 8" stand)
(47cm Deep x 41.9cm Wide x 43.8cm High)
2200°F (1204°C)
120 Volts, 13 Amps, 1560 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 5-15 (Standard Household Plug)
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. This model, used for its intended and expected purpose, would not be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model is available in 100V
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
70lb. (32Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
KH models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.

KH 418 Specifications - The KH 418 is our deepest and most popular KH Series heat treat oven. It's available in both economical and premium control designs.

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing

18" Deep x 6.5" Wide x 4.25" High - 0.29 Cubic Feet
(45.7cm Deep x 16.5cm Wide x 10.8cm High - 8.2L)
23.5" Deep x 16.5" Wide x 17.25" High (includes the 8" stand)
(59.7cm Deep x 41.9cm Wide x 43.8cm High)
2200°F (1204°C)
120 Volts, 13 Amps, 1560 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 5-15 (Standard Household Plug)
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. This model, used for its intended and expected purpose, would not be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model is available in 100V
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
75lb. (34Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
KH models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.