RM II Specifications
RM II 810 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
11.25" Diameter x 9" Deep - 0.57 Cubic Feet
(28.6cm Diameter x 22.9cm Deep - 16.1L)
22.5" Long x 16.25" Wide x 22" High (includes the 8" stand)
(57.2cm Deep x 41.3cm Wide x 55.9cm High)
2200°F (1204°C) - Cone 5-1/2 max.
120 Volts, 18 Amps, 2160 Watts, 60Hz, Single Phase (Requires a Fully Rated 20A Breaker)
Power Cord Plug Configuration - NEMA 5-20
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
62lb. (28Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
RM II models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.

RM II 1210 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing

11.25" Diameter x 13.5" Deep - 0.86 Cubic Feet
(28.6cm Diameter x 34.3cm Deep - 24.4L)
22.5" Long x 16.25" Wide x 26.5" High (includes the 8" stand)
(57.2cm Deep x 41.3cm Wide x 67.3cm High)
1800°F (982°C) - Cone 07 max.
120 Volts, 19 Amps, 2280 Watts, 60Hz, Single Phase (Requires a Fully Rated 20A Breaker)
Power Cord Plug Configuration - NEMA 5-20
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
70lb. (32Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
RM II models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.
RM II 1210-B Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
11.25" Diameter x 13.5" Deep - 0.86 Cubic Feet
(28.6cm Diameter x 34.3cm Deep - 24.4L)
22.5" Long x 16.25" Wide x 26.5" High (includes the 8" stand)
(57.2cm Deep x 41.3cm Wide x 67.3cm High)
2300°F (1260°C) - Cone 8 max.
240 Volts, 13 Amps, 3120 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 6-20
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
70lb. (32Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
RM II models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.

RM 1413 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
14.5" Diameter x 13.5" Deep - 1.30 Cubic Feet
(36.8cm Diameter x 34.3cm Deep - 36.8L)
25.75" Long x 19.5" Wide x 26.5" High (includes the 8" stand)
(65.4cm Deep x 49.5cm Wide x 67.3cm High)
2300°F (1260°C) - Cone 8 max.
240 Volts, 15 Amps, 3600 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 6-20
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
100lb. (46Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
RM II models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.

RM II 1813 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
17.5" Diameter x 13.5" Deep - 2.00 Cubic Feet
(44.5cm Diameter x 34.3cm Deep - 56.3L)
28.75" Long x 22.5" Wide x 26.5" High (includes the 8" stand)
(73cm Long x 57.2cm Wide x 67.3cm High)
2300°F (1260°C) - Cone 8 max.
240 Volts, 18 Amps, 4320 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 6-20
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
115lb. (52Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
RM II models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.

RM II 1822 Specifications

Chamber Dimensions
Outer Dimensions
Maximum Temperature
Electrical
Shipping Weight
Shipping Method
NRTL Agency Listing
17.5" Diameter x 22.25" Deep - 3.30 Cubic Feet
(44.5cm Diameter x 57cm Deep - 93L)
28.75" Long x 22.5" Wide x 35.25" High (includes the 8" stand)
(73cm Long x 57.2cm Wide x 89.5cm High)
2300°F (1260°C) - Cone 8 max.
240 Volts, 30 Amps, 7200 Watts, 60Hz, Single Phase
Power Cord Plug Configuration - NEMA 6-50
Consult with an electrician for proper fuse panel, service wire size, receptacle, and fusing requirements. It is possible that this model, when used as intended for its expected purpose, may be defined as "continuous use". Continuous use is defined as continuous, full power on for 3+ hours.
Model will operate properly on both 50Hz and 60Hz
Model not available in 3 phase Delta or Y designs
145lb. (66Kg) - Approx.
Freight Truck
TUV Listed United States and Canada - Designed and Tested to CSA & U/L 499
RM II models may contain chemicals known to the State of Calfornia to cause cancer and birth defects or other reproductive harm.